QUESTION 47
Click the Task button.
Choose the 3Com switch you would use for the Maluti University (MU) server farm solution.

A.
B.
C.
D.

Correct Answer: QUESTION 48
If you chose the Switch 5500G-EI 24 port model (3CR17250-91) for the Maluti University (MU) distribution centers, which solution would you use to connect the distribution center to the wiring closets on the upper floors?

A. Use the 10/100/1000BASE-T switch ports to connect the switch to the wiring closets
B. Use 1000BASE-SX SFP Transceivers on the SFP gigabit ports to connect the switch to the wiring closets
C. Use the 1-port 10G Application Media Module with 10GBASE-LR XFP Transceiver to connect the switch to the wiring closets
D. Use 3Com’s eXpandable Resilient Networking (XRN) Distributed Fabric technology to connect the switch to the wiring closets

Correct Answer: B
QUESTION 49
You recommended a 1000BASE-X campus-backbone solution to Maluti University (MU) to connect the four distribution buildings to the data center. MU is concerned that the 1000BASE-X campus backbone will not provide enough network bandwidth to support its combined data/voice network traffic. Which solution would you recommend to MU to alleviate this concern?

A. Use VLAN segmentation to reduce the traffic that traverses the campus backbone
B. Distribute the 28 servers, currently located in Building 9 data center, throughout the network to reduce campus-backbone traffic
C. Use the Switch 8800 in the data center and the Switch 7700 in the distribution centers, with 10 Gig Ethernet connections between the switches

Correct Answer: C
QUESTION 50
Which wiring closet solution would you use to connect the Maluti University (MU) desktop devices?
A. Switch 5500-SI 28/52 port model
B. Switch 5500-EI 28 port FX model
C. Switch 5500-EI PWR 28/52 port model
D. Switch 5500G-EI PWR 24/48 port model
Correct Answer: C

3Com 3M0-212 Exam Certification Guide presents you with an organized test preparation routine through the use of proven series elements and techniques.“Do I Know This Already?”quizzes open each chapter and allow you to decide how much time you need to spend on each section. 3Com 3M0-212 lists and Foundation Summary tables make referencing easy and give you a quick refresher whenever you need it.Challenging 3Com 3M0-212 review questions help you assess your knowledge and reinforce key concepts.3Com 3M0-212 exercises help you think about exam objectives in real-world situations,thus increasing recall during exam time.